Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Restor Dent Endod ; 48(3): e26, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37675451

RESUMO

Objective: This in vitro study aimed to evaluate the effects of different whitening toothpastes on a composite resin during at-home bleaching with 10% carbamide peroxide. Materials and Methods: Sixty samples (7 mm × 2 mm) were used for color and roughness analyses, while another 60 samples (3 mm × 2 mm) were utilized to assess microhardness. The factors analyzed included toothpaste, for which 5 options with varying active agents were tested (distilled water; conventional toothpaste; whitening toothpaste with abrasive agents; whitening toothpaste with abrasive and chemical agents; and whitening toothpaste with abrasive, chemical, and bleaching agents). Brushing and application of whitening gel were performed for 14 days. Surface microhardness (SMH), surface roughness (Ra), and color (∆L*, ∆a*, ∆b, ∆E*ab, and ∆E00) were analyzed. The Ra and SMH data were analyzed using mixed generalized linear models for repeated measures, while the color results were assessed using the Kruskal-Wallis and Dunn tests. Results: Between the initial and final time points, all groups demonstrated significant increases in Ra and reductions in SMH. No significant differences were found between groups for SMH at the final time point, at which all groups differed from the distilled water group. Conventional toothpaste exhibited the lowest Ra, while whitening toothpaste with abrasive agent had the highest value. No significant differences were observed in ∆L*, ∆a*, and ∆b. Conclusions: While toothpaste composition did not affect the color stability and microhardness of resin composite, combining toothbrushing with whitening toothpaste and at-home bleaching enhanced the change in Ra.

2.
Photodiagnosis Photodyn Ther ; 44: 103794, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37699468

RESUMO

BACKGROUND: The effectiveness of in-office bleaching protocols performed with violet LED light either combined with a bleaching agent containing 37% carbamide peroxide, or not, was determined by comparing teeth with different degrees of darkening. METHODOLOGY: Eighty bovine incisors were separated into groups of "light" teeth (luminosity greater than or equal to B3) and "dark" teeth (less than or equal to A3.5) to receive the protocols: HP - 35% hydrogen peroxide (Whiteness HP), CP - 37% carbamide peroxide (Whiteness SuperEndo), LED - violet LED light (Bright Max Whitening), CPLED - CP associated with the LED. For color analysis the CIEL*a*b* e WID, ΔEab, ΔE00 e ΔWID parameters were used. Data were analyzed using Mann-Whitney, Kruskal-Wallis, Dunn, Friedman or Nemenyi tests (α = 5%). RESULTS: HP and CP resulted in similar color change values (ΔEab, ΔE00 e ΔWID) for light and dark teeth (p > 0.05). Dark teeth showed better bleaching effectiveness (ΔEab, ΔE00 e ΔWID) than light teeth when CPLED was used (p < 0.05). LED showed color change that were below the limits of acceptability and perceptibility for ΔWID. CONCLUSION: light teeth are effectively bleached with the use of HP or CP, whereas dark teeth respond better to treatment with the CPLED protocol. Violet LED used alone did not show a satisfactory result.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareamento Dental/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Incisivo , Cor
3.
Photodiagnosis Photodyn Ther ; 44: 103762, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37640206

RESUMO

BACKGROUND: The effectiveness of dental color change was assessed by incorporating titanium dioxide (TiO2) into 37% carbamide peroxide bleaching agent associated with hybrid light. METHODOLOGY: Fifty bovine incisors were selected to receive the bleaching treatment, and separated into five groups (n = 10): 35% hydrogen peroxide (HP) (Whiteness HP, FGM/HP); 37% carbamide peroxide (CP) (Whiteness SuperEndo, FGM/CP); CP + hybrid light (HL) (CP HL); CP + 1% TiO2 (CP TiO2); CP TiO2 + hybrid light (CP TiO2 HL). The bleaching gels were applied to the dental surface for 30 min. Hybrid light (Whitening Plus, DMC/infrared laser diodes + blue LEDs +violet LEDs) was applied with 1 min of active light, alternating with 1 min of pause. A spectrophotometer (VITA Easyshade® Advance, Vita) was used to determine the color of the dental elements at baseline and time points after the 1st, 2nd and 3rd bleaching sessions. Color change effectiveness was evaluated using Vita Classical, CIEL*a*b*, WID and ΔEab, ΔE00 and ΔWID parameters. RESULTS: Generalized mixed linear models for repeated measures (α = 5%) showed significant decrease in Vita Classical scores and a* and b* values, as well as an increase in L* and ∆WID values for all the groups. Higher color change values for ΔEab were observed for CP HL and CP TiO2 HL, while those of ΔE00 and ΔWID were higher for CP TiO2 HL at the end of the bleaching treatment. CONCLUSION: Hybrid light applied with TiO2 incorporated into CP potentiated the effectiveness of the color change in the tooth structure.


Assuntos
Clareadores , Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareadores Dentários/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Ácido Hipocloroso , Incisivo , Cor
4.
J Appl Oral Sci ; 31: e20220428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37194790

RESUMO

To characterize activated charcoal and 2% hydrogen peroxide-based toothpastes and investigate their effects on roughness, color change, and gloss of bulk-fill composite resin. Composite resin specimens (Aura Bulk Fill, SDI) were subjected to 5,000 brushing cycles with regular toothpaste (Colgate Total 12, [RT]), activated charcoal toothpaste (Bianco Dental Carbon, [AC]), or hydrogen peroxide-containing toothpaste (Colgate Luminous White Advanced, [HP]), with or without coffee exposure. The pH, particle characterization by scanning electron microscopy (SEM), and weight% of solid particles in the toothpaste were assessed. Roughness (Ra) was evaluated using a surface profile-measuring device, color change (∆Eab/∆E00) by reflectance spectrophotometer, and gloss unit (GU) by glossmeter. Kruskal-Wallis, Dunn, Friedman, and Nemenyi tests were used, and the correlation coefficient test was performed between Ra and GU (α=0.05). RT presented a higher Ra after brushing and did not change after staining with coffee; moreover, the ∆Eab/∆E00 values were higher for RT than HP. Regarding gloss, AC and HP obtained higher values compared to RT. A significant negative correlation between gloss and Ra was found for RT exposed to coffee. All toothpastes had a neutral pH; however, RT had the largest percentage of solids by weight. SEM images showed particles of many sizes: irregular shape (RT), more regular particles (AC), and spherical clusters (HP). Although surface roughness, color change, and gloss may compromise the longevity of restorations, the whitening toothpastes tested did not promote more morphology changes than regular toothpastes.


Assuntos
Peróxido de Hidrogênio , Cremes Dentais , Cremes Dentais/química , Carvão Vegetal , Café , Propriedades de Superfície , Escovação Dentária/métodos , Resinas Compostas , Cor
5.
Photodiagnosis Photodyn Ther ; 42: 103631, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37236518

RESUMO

BACKGROUND: Dental color change and the temperature of the pulp chamber and of the buccal surface were evaluated during bleaching with 37% carbamide peroxide (CP) with continuous vs fractionated violet LED light protocols. METHODOLOGY: Bovine incisors received in-office bleaching for 30 min using different light protocols (Bright Max Whitening, MMOptics). Teeth were separated into groups (n = 10): HP) 35% hydrogen peroxide (Whiteness HP, FGM)/no light; CP) 37% carbamide peroxide (Whiteness SuperEndo, FGM)/no light; CP10) CP+10 min of continuous light; CP20) CP+20 min of continuous light; CP30) CP+30 min of continuous light; CPF) CP+20 cycles of 60 s light / 30 s no light (fractionated). Color evaluations were performed at different times. Evaluations of pulp and buccal surface temperatures were performed before and throughout the 30 min of bleaching. RESULTS: Generalized linear models for repeated measures over time were applied to the data (α=5%). After the 1st session, CP20 and CP30 had significantly lower b* values ​​than CP and CP10 (p = 0.0071). For ΔEab and ΔE00, CPF, CP20 and CP30 showed the highest color change among the treatments after the third bleaching (p<0.05). For temperature evaluations, CP30 showed higher pulp and buccal surface temperatures than the other protocols (p<0.0001) after 20 min. CONCLUSION: Fractionated or continuous application of violet LED for 20 or 30 min leads to greater effectiveness of color change. All protocols with the application of LED led to an increase in pulp and buccal surface temperatures during bleaching, although the fractionated application appeared to be safer than the use of continuous light.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida , Clareamento Dental/métodos , Temperatura , Polpa Dentária , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Cor
6.
Clin Oral Investig ; 27(7): 3545-3556, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995429

RESUMO

OBJECTIVES: To evaluate the effect of acid erosion on different physical properties of resin composite with S-PRG (surface pre-reacted glass) fillers, by conducting simulations of intrinsic and extrinsic sources. MATERIALS AND METHODS: Cylindrical samples (Ø6 vs. 2 mm) of a conventional nanohybrid resin composite (Forma, Ultradent) and of a nanohybrid resin composite with S-PRG filler (Beautifil II, Shofu) were exposed to erosive cycling (5 days), based on (n=12) remineralizing solution (control); 0.3% citric acid (pH=2.6); or 0.01 M hydrochloric acid (pH=2). Roughness (Ra), microhardness (KHN), and color (CIEL*a*b*, CIEDE2000, and Vita scale (SGU)) factors were analyzed at the initial and final time points, and the general color changes (ΔEab, ΔE00, ΔSGU) were calculated. Final images were obtained using scanning electron microscopy (SEM). The data were evaluated by generalized models, Mann-Whitney, Wilcoxon, Kruskal-Wallis, and Dunn tests (α=0.05). RESULTS: Regarding KHN, there was no difference between the groups or the time periods (p = 0.74). As for Ra, there was a significant increase in the Ra of both composites after cycling with hydrochloric acid, but only the resin composite with S-PRG filler showed a change in Ra after cycling with citric acid (p = 0.003). After cycling with citric and hydrochloric acid, the highest Ra values were found for the resin composite with S-PRG filler (p < 0.0001), corroborating the result of images (SEM) indicating loss of filler and porosities in this material. The resin composite with S-PRG filler showed higher ΔEab and ΔE00, in addition to more negative ΔSGU values and lower L* values after exposure to both acids, compared to the control (p < 0.05). CONCLUSION: The acidic conditions altered the roughness and color stability of the materials tested, pointing out that the resin composite containing S-PRG filler showed greater degradation of its physical properties than the conventional resin composite. CLINICAL RELEVANCE: Bioactive materials are relevant, considering that their properties interact with dental hard tissues; however, the S-PRG-based resin composite showed greater degradation under acidic conditions than the conventional resin composite.


Assuntos
Resinas Compostas , Ácido Clorídrico , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Teste de Materiais , Cor
7.
J. appl. oral sci ; 31: e20220428, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1440412

RESUMO

Abstract Objective To characterize activated charcoal and 2% hydrogen peroxide-based toothpastes and investigate their effects on roughness, color change, and gloss of bulk-fill composite resin. Methodology Composite resin specimens (Aura Bulk Fill, SDI) were subjected to 5,000 brushing cycles with regular toothpaste (Colgate Total 12, [RT]), activated charcoal toothpaste (Bianco Dental Carbon, [AC]), or hydrogen peroxide-containing toothpaste (Colgate Luminous White Advanced, [HP]), with or without coffee exposure. The pH, particle characterization by scanning electron microscopy (SEM), and weight% of solid particles in the toothpaste were assessed. Roughness (Ra) was evaluated using a surface profile-measuring device, color change (∆Eab/∆E00) by reflectance spectrophotometer, and gloss unit (GU) by glossmeter. Kruskal-Wallis, Dunn, Friedman, and Nemenyi tests were used, and the correlation coefficient test was performed between Ra and GU (α=0.05). Results RT presented a higher Ra after brushing and did not change after staining with coffee; moreover, the ∆Eab/∆E00 values were higher for RT than HP. Regarding gloss, AC and HP obtained higher values compared to RT. A significant negative correlation between gloss and Ra was found for RT exposed to coffee. All toothpastes had a neutral pH; however, RT had the largest percentage of solids by weight. SEM images showed particles of many sizes: irregular shape (RT), more regular particles (AC), and spherical clusters (HP). Although surface roughness, color change, and gloss may compromise the longevity of restorations, the whitening toothpastes tested did not promote more morphology changes than regular toothpastes.

8.
Braz. j. oral sci ; 21: e228852, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1392917

RESUMO

Aim: To evaluate the occlusal and internal marginal adaptation of inlay restorations made of different materials, using CAD-CAM. Methods: Preparations were made for MOD inlays of one-third intercuspal width and 4 mm depth in 30 third human molars. The teeth were restored using CAD-CAM materials (n=10) of nanoceramic resin (Lava Ultimate), polymer-infiltrated ceramic network (VITA ENAMIC), or lithium disilicate glass-ceramic (IPS e.max CAD). The specimens were cemented with dual resin cement and sectioned at the center of the restoration, after which the two halves were evaluated, and photographed The occlusal and internal discrepancy (µm) was determined at five points: cavosurface angle of the occlusal-facial wall (CA-O); center of the facial wall (FW); faciopulpal angle (FPA); center of the pulpal wall (PW); and center of the lingual wall (LW). The data were submitted to the Kruskal-Wallis and the Dunn tests (α=0.05). Results: No difference was observed among the materials regarding the occlusal discrepancy at the CA-O, FPA, or PW internal points. The e.max CAD measurement at FW showed larger internal discrepancy than that of Lava (p=0.02). The internal discrepancy at LW was greater for e.max CAD than VITA ENAMIC (p=0.02). Conclusion: Lithium disilicate glass-ceramic presented greater internal discrepancy in relation to the surrounding walls of the inlay preparations


Assuntos
Cerâmica , Desenho Assistido por Computador , Adaptação Marginal Dentária , Materiais Dentários , Restaurações Intracoronárias
9.
J Prosthet Dent ; 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35843750

RESUMO

STATEMENT OF PROBLEM: Achieving accurate tooth color is important in esthetic dental treatments; however, clinical studies evaluating how ceramic veneer procedures affect color alterations are lacking. PURPOSE: The purpose of this clinical study was to assess the color alteration during treatment with ceramic veneers and to correlate these changes with the tooth treated and veneer thickness. MATERIAL AND METHODS: Ten patients who underwent esthetic treatment were enrolled as participants. Color analysis with the VITA spectrophotometer was performed at baseline, after tooth preparation, immediately after cementation (Final 1), and after 6 to 12 months of follow-up (Final 2). Data of L∗, a∗, b∗, shade guide unit (SGU), ΔEab, ΔE00, and variation in SGU (ΔSGU) were obtained. Thickness of the veneer was also recorded. Each participant was considered as a statistical block, and the mean results for each tooth (maxillary central incisors, lateral incisors, and canines) were presented. Data were evaluated by the mixed model for repeated measures and Tukey-Kramer post hoc test (L∗, a∗, b∗), generalized linear models (thickness, ΔEab, ΔE00, SGU), Friedman test (ΔSGU), and the Pearson test was used to correlate veneer thickness and color change (ΔEab, ΔE00, ΔSGU) (α=.05). RESULTS: Among the teeth treated, no differences were found in ceramic thicknesses. The mean thickness was 1.03 mm for central incisors, 0.96 for lateral incisors, and 0.89 for canines. The b∗ values increased significantly after preparation and decreased after cementation (P<.001). For ΔEab, ΔE00, and ΔSGU, there was no statistically significant difference between the types of tooth at each respective time of analysis (P>.05). Regardless of the tooth, a decrease in the SGU score was detected after cementation (P=.015). After tooth preparation, there was significant correlation (P<.05) between ceramic thickness and ΔSGU (r=0.36). CONCLUSIONS: Treatment with ceramic veneers resulted in color change, mainly with respect to the b∗ axis (yellow), producing objective differences in the ΔE analysis. Although ceramic thickness correlated with the VITA scale change (ΔSGU) after tooth wear or preparation, ceramic thickness did not differ among tooth types and did not correlate with changes in color parameters after cementation. (P>.05).

10.
Braz Oral Res ; 36: e097, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35830141

RESUMO

Titanium dioxide nanotubes (TiO2-nts) were incorporated into a glass ionomer cement (GIC) with improved mechanical properties and antibacterial activity. The aims of the present in vitro study were to define the elemental characterization, aluminum (Al) release rate, and initial working time for GIC reinforced with TiO2-nts, in an experimental caries model. TiO2-nts were incorporated into GIC powder components at 5% by weight, and compared with unblended GIC. Experimental approaches used energy-dispersive spectrometry (EDS), atomic absorption spectrophotometry (AAS), and brightness loss to define surface element properties, Al release rates, and initial working time, respectively. Statistical analysis was performed by 2-way ANOVA, Tukey's test, generalized linear models, and Student's t test (a = 0.05). EDS data analysis revealed that TiO2-nts incorporated into GIC had no significant impact on the typical elemental composition of GICs in an in vitro caries model. Regarding the demineralizing solution, GIC with TiO2-nt significantly decreased the Al release rate, compared with the control group (p < 0.0001). Moreover, TiO2-nt incorporated into GIC did not alter the initial working time of the material (p > 0.05). These findings add information to our scientific body of knowledge concerning the potential impact of TiO2-nt on the performance of conventional GICs.


Assuntos
Cimentos de Ionômeros de Vidro , Nanotubos , Alumínio , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Titânio
11.
J Esthet Restor Dent ; 34(6): 969-977, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35332985

RESUMO

OBJECTIVE: To investigate, in vitro, the influence of at-home bleaching with 16% carbamide peroxide (CP) gels containing different thickeners on the color, gloss, roughness, and microhardness of a composite resin with bisphenol A (BPA) and without bisphenol A (BPA-free). MATERIAL AND METHODS: Cylindrical samples (7 × 2 mm) of a composite resin with BPA (Filtek Z350 XT®; 3M/ESPE) and composite resin BPA-free (Vittra APS®; FGM) were subdivided into six subgroups (n = 12), according to the bleaching gel used: no bleaching (control), commercial gel with 16% CP and carbopol, experimental gel with 16% CP and carbopol, experimental gel with 16% CP and natrosol, experimental gel with carbopol and experimental gel with natrosol. At the end of the experimental phase, the specimens were analyzed for color (ΔE*ab and ΔE00 ), surface roughness (Ra), gloss (GU), and surface microhardness (SMH). The data for all analyzes were submitted to Levene's test, Shapiro-Wilk's test and ANOVA. RESULTS: For ΔE*ab and ΔE00 no statistically significant differences were found between all groups evaluated. Bleaching with experimental 16% CP gel with carbopol resulted in the lowest GU values for both composite resins evaluated. 16% CP experimental gel with natrosol resulted in higher Ra for the BPA composite resin and the bleaching with natrosol resulted in higher Ra for BPA-free. About 16% CP experimental gel with carbopol and 16% CP experimental gel with natrosol resulted in the lowest final SMH for composite resin with BPA. For the BPA-free composite resin, no differences were found between the groups in SMH for the same resin, however they presented the lowest values compared with all others groups. CONCLUSION: The effects on physical properties are dependent on the composition of the composite resin and the thickener/bleaching gel used. The BPA-free composite resin showed less changes after exposure to bleaching agent, although its initial physical properties were worse compared to a bleached BPA. CLINICAL RELEVANCE: The hydrogen peroxide and thickener of the at-home bleaching gel does impact the properties of composites with BPA or BPA-free such as gloss, roughness and surface microhardness, extremely important factors for maintaining an aesthetically and physically satisfactory restoration. BPA-free composite resins have inferior properties after at-home bleaching with different thickeners.


Assuntos
Clareamento Dental , Compostos Benzidrílicos , Peróxido de Carbamida , Resinas Compostas , Géis , Peróxido de Hidrogênio , Teste de Materiais , Peróxidos , Fenóis , Propriedades de Superfície , Clareamento Dental/métodos , Ureia
12.
Am J Dent ; 35(1): 37-42, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35316591

RESUMO

PURPOSE: To evaluate the effect of polishing systems (discs or rubbers) on surface roughness (Ra) and color change (ΔE) of two bulk fill and one conventional resin composite after immersion in a dye solution. METHODS: 180 samples (10 mm x 2 mm) were separated into three groups: (1) Resin composite: Filtek One Bulk Fill (FO), Tetric N-Ceram Bulk Fill (TNC), Filtek Z350 XT (FXT) (n= 60); (2) polishing system: unpolished (control); aluminum oxide discs (Sof-Lex, AOD); cup-shaped abrasive rubber polishers (Astropol, CSA) (n= 20), and (3) immersion solutions: coffee or distilled water (n= 10). Immersion was under 5 mL of each solution for 3 hours daily, for 30 days. Measurement of Ra and ∆E was made considering two times: initial (after polishing) and final (after immersion), in addition to surface analysis by scanning electron microscopy at the end. Kruskal-Wallis, Mann-Whitney, and Dunn (α= 0.05) was used. RESULTS: For the unpolished samples after immersion in coffee, TNC (P= 0.007) showed lower ΔE than FXT and FO. For polished samples with CSA and immersed in coffee, TNC followed by FXT showed lower ΔE than in the absence of polishing. Polishing with AOD and immersed in coffee: FO had smaller ΔE than when not polished. For Ra, TNC and FO had lower values after using AOD, whereas for FXT lower Ra was noted with CSA. CLINICAL SIGNIFICANCE: The roughness and color stability of resin composites are mediated by the polished material, polishing system and dye solution. The best results were found for Tetric N-Ceram polished with aluminum oxide discs.


Assuntos
Óxido de Alumínio , Polimento Dentário , Polimento Dentário/métodos , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
13.
Rev. odontol. UNESP (Online) ; 51: e20220032, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1424232

RESUMO

Abstract Introduction composite resins are indicated to the reconstruction of proximal walls and the evaluation of properties of flow bulk-fill composite resins exposed to acid challenge is necessary. Objective to evaluate the microhardness and roughness at different depths of photoactivation of bulk-fill flow composites (Filtek Bulk Fill Flow; SureFil SDR Flow; Tetric N Ceram Bulk fill) and conventional composite resin (control, Filtek Z350 XT) subjected to acid challenge. Material and method forty composites brick shaped specimens (3x3x4 mm) were made using a polyacetal matrix. To simulate pH challenges, the samples were immersed in a demineralizing solution. Each sample had Knoop microhardness (KHN) and roughness (Ra) evaluated at three depths (superficial, medium, and cervical), considering the lateral surface of the sample. Data were submitted to Kruskal-Wallis, Friedman's and Dunn's tests with a significance level of 5%. Result comparing the composites among themselves, in superficial (p=0.693), medium (p=0.053) and cervical (p=0.176) regions, there was no difference in the KHN values. There were also no differences in roughness between the composites in superficial (p=0.356), medium (p=0.734) and cervical (p=0.207) regions. Only the Filtek Z350 XT (p=0.027) showed less difference in KHN in the middle region caused by acid challenge. Changes in roughness showed that the greatest difference was at the cervical region for Bulk Fill Flow SDR (p=0.014) and Tetric N-Ceram Bulk Fill (p = 0.003) with an increase after acid challenge. Conclusion after acid challenge, bulk-fill flow composites showed alterations similar to those presented by the conventional nanoparticulate resin composite.


Resumo Introdução as resinas compostas são indicadas para reconstrução de paredes proximais e a avaliação das propriedades das resinas compostas bulk-fill flow expostas ao desafio ácido mostra-se necessária. Objetivo avaliar a microdureza e rugosidade em diferentes profundidades de fotoativação de resinas compostas bulk-fill flow (Filtek Bulk Fill Flow; SureFil SDR Flow; Tetric N Ceram Bulk fill) e convencional (controle, Filtek Z350 XT) submetidas ao desafio ácido. Material e método quarenta amostras retangulares (3x3x4 mm) foram confeccionadas utilizando uma matriz de poliacetal. Para simular o desafio ácido, as amostras foram imersas em uma solução desmineralizante. Cada amostra teve a microdureza Knoop (KHN) e rugosidade (Ra) avaliadas em três profundidades (superficial, média e cervical), considerando a superfície lateral da amostra. Os dados foram submetidos aos testes de Kruskal-Wallis, Friedman e Dunn com nível de significância de 5%. Resultado comparando as resinas compostas entre si, nas regiões superficial (p=0,693), média (p=0,053) e cervical (p=0,176), não houve diferença nos valores de KHN. Também não houve diferenças na rugosidade entre os materiais nas regiões superficial (p=0,356), média (p=0,734) e cervical (p=0,207). Apenas o Filtek Z350 XT (p=0,027) apresentou menor diferença de KHN na região intermediária causada pelo desafio ácido. As mudanças na rugosidade mostraram que a maior diferença foi na região cervical para Bulk Fill Flow SDR (p=0,014) e Tetric N-Ceram Bulk Fill (p=0,003), com aumento após o desafio ácido. Conclusão após desafio ácido, as resinas compostas bulk-fill flow apresentaram alterações semelhantes às apresentadas pela resina composta convencional nanoparticulada.


Assuntos
Estatísticas não Paramétricas , Resinas Compostas , Cárie Dentária , Restauração Dentária Permanente , Cura Luminosa de Adesivos Dentários , Testes de Dureza
14.
Braz. oral res. (Online) ; 36: e097, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384189

RESUMO

Abstract Titanium dioxide nanotubes (TiO2-nts) were incorporated into a glass ionomer cement (GIC) with improved mechanical properties and antibacterial activity. The aims of the present in vitro study were to define the elemental characterization, aluminum (Al) release rate, and initial working time for GIC reinforced with TiO2-nts, in an experimental caries model. TiO2-nts were incorporated into GIC powder components at 5% by weight, and compared with unblended GIC. Experimental approaches used energy-dispersive spectrometry (EDS), atomic absorption spectrophotometry (AAS), and brightness loss to define surface element properties, Al release rates, and initial working time, respectively. Statistical analysis was performed by 2-way ANOVA, Tukey's test, generalized linear models, and Student's t test (a = 0.05). EDS data analysis revealed that TiO2-nts incorporated into GIC had no significant impact on the typical elemental composition of GICs in an in vitro caries model. Regarding the demineralizing solution, GIC with TiO2-nt significantly decreased the Al release rate, compared with the control group (p < 0.0001). Moreover, TiO2-nt incorporated into GIC did not alter the initial working time of the material (p > 0.05). These findings add information to our scientific body of knowledge concerning the potential impact of TiO2-nt on the performance of conventional GICs.

15.
J Clin Exp Dent ; 12(2): e116-e122, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32071692

RESUMO

BACKGROUND: Commercial bleaching gels with remineralizing agents were developed to reduce the adverse effects of dental bleaching. The present study evaluated the effects on teeth of in-office bleaching gels containing 35-40% hydrogen peroxide (HP) with Calcium (Ca) or Fluoride (F). MATERIAL AND METHODS: Bovine enamel/dentin blocks (4x4x2.5 mm) were randomly divided into the following groups (n=12): no treatment (control); 35% HP (Whiteness HP, FGM); 35% HP with Ca (Whiteness HP Blue, FGM); 40% HP with F (Opalescence Boost, Ultradent). The specimens were analyzed for color (ΔL*, Δa*, Δb*, and ΔE), roughness (Ra), and Knoop microhardness (KHN). The color and KHN data were submitted to ANOVA and Tukey's test, while Ra values were analyzed using mixed models for repeated measures and Tukey-Kramer's test (α=0.05). RESULTS: The bleached groups did not exhibit statistical differences among them for color. For roughness, 35% HP provided a slight increase of Ra, which was statistically different from the control. For microhardness, 35% HP and 40% HP with F presented KHN values that were statistically lower from the control, while the 35% HP with Ca did not statistically differ from the control. CONCLUSIONS: The presence of Ca or F in bleaching gels did not interfere with bleaching efficacy. However, only the enamel exposed to the bleaching gel containing Ca obtained microhardness values similar to unbleached enamel. Key words:Hydrogen peroxide, tooth bleaching, tooth bleaching agents, laboratory research.

16.
Braz. dent. sci ; 23(3): 1-8, 2020. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1117327

RESUMO

Objective: This study aimed to evaluate the surface microhardness and morphology, as well as the microshear bond strength of a self-etching adhesive (Clearfil SE, Kuraray) to eroded dentin, exposed or not to cigarette smoke. Forty dental crowns were divided into 4 groups (n = 10): no treatment (control) (C); erosion (E); erosion + cigarette smoke exposure (ES); cigarette smoke exposure (S). Samples were prepared through third molars polishing until dentin exposure, followed by crown section. Erosive cycles were performed 5 times/day for 30 s at 60 min intervals. Cigarette smoke was produced with twenty cigarettes/day, during 5 days. Microhardness was evaluated initially and after the treatments. Microshear bond strength was tested after the treatments and dentin restoration with flow composite. Failure patterns and dentin morphology was evaluated by Scanning Electron Microscopy. Microshear bond strength data was submitted to two-way ANOVA, microharness test was adjusted by gamma distribution to be a non-parametric analyses (p=0.05), and surface morphology as qualitative analyses. Loss percentage of microhardness was observed only in groups submitted to erosion. Bond strength was statistically similar between all groups. The most prevalent failure pattern was of adhesive type. Morphological analysis of dentin showed obliterated tubules in groups submitted to cigarette smoke exposure. Cigarette smoke exposure did not promote any effect in the percentage of microhardness loss, as in sound dentin as in eroded dentin. Cigarette smoke, erosion, and association of both, did not alter the bond strength of self-etching adhesives to dentin. (AU)


Objetivo: Este estudo teve como objetivo avaliar a microdureza (% perda de dureza) e morfologia de superfície (MS), assim como a resistência de união (RU) de um adesivo autocondicionante (Clearfil SE, Kuraray) à uma dentina erodida, exposta ou não à fumaça de cigarro. Material e Métodos: Quarenta coroas dentais de terceiros molares foram seccionadas da raiz e polidas até a exposição dentinária, sendo aleatoriamente divididas em 4 grupos (n=10): sem tratamento (controle), erosão (E), erosão+ exposição a fumaça de cigarro (ES); exposição a fumaça de cigarro (S).O ciclo erosivo foi realizado 5 vezes/dia por 30s, com 60 minutos de intervalo entre eles. Os grupos ES e S foram exposto à fumaça de cigarro produzida por 20 cigarros/dia, durante 5 dias. A avaliação da microdureza foi realizada antes e após os tratamentos, enquanto a resistência da união por microcisalhamento foi realizada após os tratamentos Os padrões de fratura representativos e a MS dentinária foram avaliados por microscopia eletrônica de varredura (MEV). Os dados de RU foram analisados por ANOVA dois fatores, enquanto a análise de microdureza foi ajustada por distribuição gama por ser uma análise não-paramétrica (p=0.05). A MS foi analisada qualitativamente. Resultados: Os grupos expostos aos ciclos erosivos (E e ES) apresentaram % de perda de dureza significativamente menor que os grupos não expostos (Controle e S. aos ciclos erosivos (E e ES). Para RU, não houve diferença estatística significativa entre os grupos. O padrão de fratura mais observado foi do tipo adesivo, e através das imagens obtidas por MEV, observou-se a obliteração de túbulos dentinários no grupo exposto à fumaça de cigarro, enquanto os grupos submetidos aos ciclos erosivos (E e ES) apresentaram maior exposição e diâmetro de túbulos dentinários. Conclusão: A exposição à fumaça de cigarro não promove nenhum efeito quanto a perda de porcentagem de dureza dentinária, assim como em dentina erodida e saudável. A fumaça de cigarro, o processo erosivo, e a associação de ambos, não altera a resistência da união de adesivos autocondicionantes à dentina. (AU)


Assuntos
Resistência à Tração , Erosão Dentária , Coroas , Cimentos Dentários , Produtos do Tabaco
17.
Eur J Dent ; 13(2): 199-205, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31476775

RESUMO

OBJECTIVE: The main purpose of this study was to evaluate the effect of dentin pretreatment with 8% arginine on the immediate and 6-month bond strength (BS) of adhesive systems and surface morphology of dentin. MATERIALS AND METHODS: Dentin bovine specimens (5 × 5 mm) were allocated into following pretreatments: without pretreatment (conventional technique, C) or exposure to arginine solution (A) for 5 minutes prior to tooth restoration. The adhesive procedure was performed using (n = 12): 3-step etch-and-rinse adhesive (Scotchbond Multipurpose-SBMP [C+SBMP and A+SBMP]); 2-step etch-and-rinse adhesive (Single Bond 2 - SB [C+SB and A+SB]); or 2-step self-etch adhesive (Clearfil SE Bond - CSEB [C+CSEB and A+CSEB]). After 24 hours, the composite resin restorations were evaluated immediately and after 6 months of water storage using a microshear test and fracture pattern. The dentin surface exposed to A was assessed by scanning electron microscopy (SEM). The immediate BS data were submitted to a two-way analysis of variance and Tukey's test, and the long-term BS results were analyzed using Kruskal-Wallis and Dunn tests (α = 0.05). RESULTS: There was a significant decrease in immediate and 6-month BS for the A+SB and A+CSEB groups, which differed statistically from the C group. The fracture pattern was predominantly adhesive for SB and CSEB adhesive for C and A. The SEM images presented a different conditioning pattern of the dentin exposed to A. CONCLUSION: The dentin pretreatment with arginine interfered negatively in the immediate and long-term BS of the simplified adhesive system. However, the SBMP adhesive was not affected by arginine pretreatment presenting the most satisfactory results.

18.
J Clin Exp Dent ; 10(8): e815-e820, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30305882

RESUMO

BACKGROUND: To establish the correlation between enamel roughness and color change of tooth. MATERIAL AND METHODS: Enamel/dentin blocks (5 x 5 x 3.2 mm) were serially ground with the following abrasive paper: 1200-grit, 800-grit, and 600-grit SiC papers. In the paired model, the analyses of color (L*, a*, b*, ΔE) and roughness (Ra) were performed among the sandpaper exposure. The data were subjected to ANOVA using models for repeated measures followed by the Tukey test. The Pearson correlation test was used to determine whether there was a relationship between Ra values and color results (α = 0.05). RESULTS: The L* values decreased in accordance with the increase of Ra, with statistical difference between all the times (p<0.05). A correlation was found between the Ra vs. the L* values (r = -0.67; p<0.0001) and ∆Ra vs. ∆a* values (r = 0.29; p = 0.05); besides that, there was no significant correlation with b* values or significant alteration in the ∆E values (p>0.05). CONCLUSIONS: The alteration of enamel roughness acted on the lightness and the green-red axis of tooth color. However, there was no significant correlation between the alteration of roughness of enamel and general color change of tooth. Key words:Surface properties, tooth discoloration, color.

19.
Braz. dent. sci ; 21(1): 17-25, 2018. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-881814

RESUMO

Objective: To evaluate the effect of 35% hydrogen peroxide (35% HP) combined to different concentrations of nanohydroxyapatite (nHA) on the effectiveness of dental bleaching (superficial enamel and deep dentin) and enamel bond strength. Material and Methods: Fifty bovine dental specimens (5x5x2mm) were divided into 5 groups, according to the treatments (n = 10): no bleaching (negative control); 35% HP (positive control); 35% HP+ 5% nHA; 35% HP + 10% nHa; and 35% HP + 15% nHA. Three in-office bleaching sessions were made. The color analysis was performed on the enamel surface and the opposite dentin, using a spectrophotometer. The results were expressed in the CIE L*a*b* system. After this, the adhesive system was applied to the tooth structure, and the dental specimens received a composite restoration. The microshear bond strength test was performed 24 h after the restoration. Data were submitted to ANOVA and Tukey's test (α=0.05). Results: For the enamel color analysis, all bleached groups differed statistically from the unbleached group, with increasing L* values and decreasing b* values. The addition of different concentrations of nHA did not interfere with the bleaching effectiveness for the enamel and opposite dentin. For microshear bond strength, no statistically significant differences were presented between groups. The adhesive failure rate of the 35% HP + 10% nHA group was lower than the 35% HP group and similar to the negative control. Conclusion: The addition of different concentrations of nHA in 35% of hydrogen peroxide did not interfere with the bleaching efficacy of enamel and deep dentin and did not affect the enamel bond strength after bleaching.(AU)


Objetivo: avaliar o efeito do peróxido de hidrogênio a 35% (HP 35%) associado a diferentes concentrações de nanohidroxiapatita (nHA) sobre a efetividade clareadora do esmalte superficial, dentina profunda e da força de adesão ao esmalte. Material e Métodos: Cinquenta espécimes bovinos (5x5x2mm) foram divididos 5 grupos (n = 10): sem clareamento (controle negativo); HP 35% (controle positivo); HP 35% + nHA 5%; HP 35% + nHA 10%; e HP 35% + nHA 15%. Três sessões de clareamento de consultório foram realizadas. A análise de cor foi realizada na superfície do esmalte e na dentina oposta e os resultados expressos no sistema CIE L*a*b*. Depois disso, os sistemas adesivos foram aplicados no esmalte, e os blocos receberam uma restauração em resina composta. O teste microcisalhamento foi realizado 24 h após a restauração. Os dados foram submetidos à ANOVA e ao teste de Tukey (α = 0,05). Resultados: Para a análise de cor do esmalte, todos os grupos clareados diferiram estatisticamente do grupo não clareado. A adição de diferentes concentrações de nHA não interferiu com a eficácia clareadora para o esmalte e dentina. Para o microcisalhamento, não houve diferença entre os grupos. A taxa de falha adesiva do grupo HP 35% + nHA 10% foi menor do que o grupo HP 35% e similar ao controle negativo. Conclusão: a adição de diferentes concentrações de nHA em PH 35% não interferiu na eficácia clareadora do esmalte e da dentina e não afetou a força de adesão do esmalte após o clareamento (AU)


Assuntos
Bovinos , Esmalte Dentário , Resistência ao Cisalhamento , Clareamento Dental
20.
Clin Cosmet Investig Dent ; 9: 27-31, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28652816

RESUMO

BACKGROUND: In daily clinical practice, esthetics of anterior teeth is a common presenting complaint of patients. OBJECTIVE: This case report discusses the management of asymmetric smile associated with unsatisfactory extensive composite restorations and describes a clinical protocol using the direct composite resin for smile enhancement to restore the dental harmony of anterior teeth. METHODS: The treatment planning was based on a diagnostic wax-up and cosmetic mock-up. After clinical and patient approvals were obtained, the patient was subjected to direct and indirect restorative treatment. CONCLUSION: Nanocomposites are an effective alternative for anterior teeth restorations. Additionally, good planning enables satisfactory esthetic results, leading to the correction of an inappropriate axial inclination of incisors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...